captive_portal: ### RS485 uart: id: modbus_serial rx_pin: 1 tx_pin: 2 baud_rate: 4800 stop_bits: 1 modbus: id: modbus1 uart_id: modbus_serial modbus_controller: - id: con_modbus_name update_interval: 11s address: 0x1 command_throttle: 150ms setup_priority: -10 sensor: - platform: modbus_controller name: "Moisture WC" id: WC address: 0x0000 unit_of_measurement: "%" register_type: read value_type: U_WORD accuracy_decimals: 1 filters: lambda: return x / 10; state_class: measurement - platform: modbus_controller name: "Temp" id: C address: 0x0001 unit_of_measurement: "°C" register_type: read value_type: U_WORD accuracy_decimals: 1 filters: lambda: return x / 10; state_class: measurement - platform: modbus_controller name: "Conductivity 1 dS/m = 1 mS/cm" id: EC address: 0x0002 unit_of_measurement: "ms/cm" register_type: read value_type: U_WORD accuracy_decimals: 1 filters: lambda: return x / 100; state_class: measurement